How to Repair a Defunct Drive by IBM ServeRAID Manager 9
Environment
Introduction
Received a notification of defunct drive
Solutions
Run a IBM ServeRAID Manager connecting to the server for the FRU part number
Then, went to remove the defunct drive
When removed, should show
Now, Replaced the hard disk to be FRU - 90P1310, because it's the same connectivity - Ultra320 SCSI - 80 pin Centronics (SCA-2) as the FRU - 397310 one
Scanned for the new hard drive
Then, set it to be a hot-spare drive
That can also be via a wizard
References
- IBM ServeRAID Manager 9
Introduction
Received a notification of defunct drive
This message was generated by the ServeRAID Manager Agent.
Please do not reply to this message.
Event Description: Defunct drive: controller 1, channel 2, SCSI ID 3 (Vendor: IBM-ESXS Model: ST314670).
Event Type: Error
Event Source: storage@hostname
Date: MM/DD/YYYY
Time: HH:MM:SS PM CST
Solutions
Run a IBM ServeRAID Manager connecting to the server for the FRU part number
Then, went to remove the defunct drive
When removed, should show
Now, Replaced the hard disk to be FRU - 90P1310, because it's the same connectivity - Ultra320 SCSI - 80 pin Centronics (SCA-2) as the FRU - 397310 one
- IBM 90P1310 hard drive specifications - http://www.testhdd.com/IBM-hard-drive-146-GB-Ultra320-SCSI-1458.html
- IBM 39R7310 hard drive specifications - http://www.testhdd.com/IBM-hard-drive-146-GB-Ultra320-SCSI-1589.html
Scanned for the new hard drive
Then, set it to be a hot-spare drive
That can also be via a wizard
References
- Removing a defunct drive - http://publib.boulder.ibm.com/infocenter/director/v5r2/index.jsp?topic=/serveraid_5.20/fqy0_aremovdd.html
- ServeRAID recovery from single defunct disk drive (DDD) failures - Servers and IntelliStation - http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-40364
- ServeRAID drive state descriptions - Servers and IntelliStation - http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=MIGR-4R6MXK