Veeam: Preparing replica VM Error: The operation has timed out with vCenter's Hardware Alarm
Received a noticed from the vCenter.
Alarm alarm.HostErrorAlarm on Host : A.B.C.D is Gray
Target: A.B.C.D
Stateless event alarm
Alarm Definition:
([Event alarm expression: Host error] OR [Event alarm expression: Host warning])
Event details:
Error detected on A.B.C.D in Pak Tin: Agent can't send heartbeats: Host is down
Target: A.B.C.D
Stateless event alarm
Alarm Definition:
([Event alarm expression: Host error] OR [Event alarm expression: Host warning])
Event details:
Error detected on A.B.C.D in Pak Tin: Agent can't send heartbeats: Host is down
One datastore was inaccessible:
At the same time, notices from the Veeam
[Failed] Replication: Machine-01 (1 machines) 1 failed
Preparing replica VM Error: The operation has timed out
Error: The operation has timed out
Preparing replica VM Error: The operation has timed out
Error: The operation has timed out
Not only the Replication Failed, it affected the VM(s) of another Virtual Disk on the ESX server.
Ping the ESX Server:
icmp_seq=0 ttl=64 time=0.852 ms
Ping the VM(s)
Request timed out
Destination host unreachable
Changed the Server to be Maintenance Mode, then rebooted it.
To the Computer Room, checking the Hardware Health of the ESX Server:
One RAID1 failed fully. There was no the Virtual Disk 1:
Replaced the Hard Disk that had the slot showing wrong led, then "Degraded", the RAID did not back to work:
Finally, required to replace another Hard Disk. Then, a new RAID1 building:
All the VM(s) of another Virtual Disk on the Server were back to normal.
As the VM(s) of the failed RAID1 were testing machines, it did not affect any services.
References
https://serverfault.com/questions/1147655/dell-poweredge-r740-stuck-in-boot-loop-with-uefi0116-error
Managing preserved cache, Dell PowerEdge RAID Controller 9 User’s Guide H330, H730, and H830 , https://www.dell.com/support/manuals/zh-hk/poweredge-rc-h730/perc9ugpublication/managing-preserved-cache?guid=guid-3a82d9bf-1ad7-4229-bdf2-fdeeec45045d&lang=en-us
Degraded state of virtual disks, Dell PowerEdge RAID Controller 9 User’s Guide H330, H730, and H830 , https://www.dell.com/support/manuals/zh-hk/poweredge-rc-h830/perc9ugpublication/degraded-state-of-virtual-disks?guid=guid-ad0c0a0b-6f1b-4dd4-a4d0-775c84a6fe60&lang=en-us#:~:text=Loading%2C%20Please%20wait-,Degraded%20state%20of%20virtual%20disks,the%20virtual%20disk%20become%20degraded